Contact with hidden service
Electric shock or water/gas/process release
Work crew
Drawings, scanning and permit
Field-verify penetration point with an authorized person
Review the critical hazards, potential consequences, persons at risk and recommended control measures for Wall / Floor Penetration in one professional HSE workspace.
Review the key hazards, consequences and control measures for Wall / Floor Penetration in a structured professional HSE format.
Electric shock or water/gas/process release
Work crew
Drawings, scanning and permit
Field-verify penetration point with an authorized person
Struck-by injury
Workers below
Exclusion zone below
Support cut sections in a controlled manner
Serious injury or fatality
Site workers
Opening-protection plan
Install suitable guardrails or covers immediately after opening is created
Fall from height or fatality
Site workers
Cover and barricade system
Physically protect the opening immediately after creation
Electric shock or release
Penetration crew
Scanning and permit system
Scan and verify the penetration area before work
Dropped-object injury
Personnel below
Exclusion zone and section securing
Mechanically support the cut section before separation
Cover failure and fall through opening
Workers performing the activity and nearby personnel
Authorized personnel, pre-work checks, suitable equipment and site procedures
Verify covers are capable of supporting expected loads
Laceration or equipment damage
Workers performing the activity and nearby personnel
Authorized personnel, pre-work checks, suitable equipment and site procedures
Protect or appropriately deburr sharp edges
Incorrect use or loss of safety control
Workers performing the activity and nearby personnel
Authorized personnel, pre-work checks, suitable equipment and site procedures
Clearly identify all penetrations
Explore related activities, hazards and control measures from the same HSE risk category.
Use these ready hazards as your starting point, customize controls, evaluate risk levels and prepare your project-specific assessment in SERNEM.
Start Risk Assessment| ACTIVITY | Wall / Floor Penetration | CATEGORY | Construction |
| # | Activity | Hazard | Consequence | Persons at Risk | Existing Risk Control | L | S | Risk | Action Required / Additional Controls | Person in Charge | Due Date | RL | RS | Residual Risk |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | Wall / Floor Penetration | Contact with hidden service | Electric shock or water/gas/process release | Work crew | Drawings, scanning and permit | 3 | 4 | 12 High | Field-verify penetration point with an authorized person | - | - | 2 | 2 | 4 Low |
| 02 | Wall / Floor Penetration | Debris falling to lower level | Struck-by injury | Workers below | Exclusion zone below | 2 | 3 | 6 Medium | Support cut sections in a controlled manner | - | - | 1 | 2 | 2 Low |
| 03 | Wall / Floor Penetration | Fall through new opening | Serious injury or fatality | Site workers | Opening-protection plan | 2 | 5 | 10 High | Install suitable guardrails or covers immediately after opening is created | - | - | 2 | 2 | 4 Low |
| 04 | Wall / Floor Penetration | Fall hazard after creating opening | Fall from height or fatality | Site workers | Cover and barricade system | 3 | 5 | 15 High | Physically protect the opening immediately after creation | - | - | 2 | 2 | 4 Low |
| 05 | Wall / Floor Penetration | Contact with hidden electrical or process line | Electric shock or release | Penetration crew | Scanning and permit system | 3 | 4 | 12 High | Scan and verify the penetration area before work | - | - | 2 | 2 | 4 Low |
| 06 | Wall / Floor Penetration | Cut section falling to lower level | Dropped-object injury | Personnel below | Exclusion zone and section securing | 3 | 3 | 9 Medium | Mechanically support the cut section before separation | - | - | 1 | 2 | 2 Low |
| 07 | Wall / Floor Penetration | Insufficient load capacity of penetration cover | Cover failure and fall through opening | Workers performing the activity and nearby personnel | Authorized personnel, pre-work checks, suitable equipment and site procedures | 2 | 3 | 6 Medium | Verify covers are capable of supporting expected loads | - | - | 1 | 2 | 2 Low |
| 08 | Wall / Floor Penetration | Sharp edge around penetration | Laceration or equipment damage | Workers performing the activity and nearby personnel | Authorized personnel, pre-work checks, suitable equipment and site procedures | 2 | 3 | 6 Medium | Protect or appropriately deburr sharp edges | - | - | 1 | 2 | 2 Low |
| 09 | Wall / Floor Penetration | Incorrect or inadequate penetration identification | Incorrect use or loss of safety control | Workers performing the activity and nearby personnel | Authorized personnel, pre-work checks, suitable equipment and site procedures | 2 | 3 | 6 Medium | Clearly identify all penetrations | - | - | 1 | 2 | 2 Low |