Electrical Critical Safety Rules

De-Energize • Lock Out • Verify Absence of Voltage

OSHA 1910 Subpart SLOTO • Shock • Arc FlashISO 45001 Framework

Document

SB-EL-001

Revision 1.0

EN
SafeBase QR

Scan

Checklists, toolbox talks and professional guides

SafeBase Pre-Job Control

Check Before Starting

30 SEC CHECK
Permit and Risk Assessment
Energy Sources
LOTO
Absence-of-Voltage Test
Qualified Person
GFCI / RCD
Barriers and PPE
01MANDATORY

De-Energize

  • Identify every electrical energy source before work.
  • De-energize equipment whenever work can be performed safely without power.
  • Never treat a control switch as an energy-isolating device.
02MANDATORY

Apply LOTO

  • Lock and tag all electrical isolating devices.
  • Each authorized worker must apply a personal lock.
  • Control re-energization in accordance with the approved procedure.
03MANDATORY

Verify De-Energization

  • Use a suitable and properly functioning test instrument.
  • Verify the tester on a known source before and after testing.
  • Confirm absence of voltage on every phase and conductor.
04MANDATORY

Qualified Persons Only

  • Electrical work must be performed by trained and qualified persons.
  • Only qualified persons may test or work on exposed energized parts.
  • Verify competence for the task, equipment and hazards involved.
05WARNING

Inspect Equipment

  • Inspect cords, plugs, receptacles, panels and tools before use.
  • Never use equipment with damaged insulation or exposed conductors.
  • Tag defective equipment and remove it from service immediately.
06WARNING

Ground-Fault Protection

  • Use suitable GFCI or RCD protection where required.
  • Verify grounding conductors and protective devices.
  • Never bypass or defeat electrical protective devices.
07WARNING

Control the Work Area

  • Barricade open panels and exposed electrical hazards.
  • Keep unauthorized persons outside established approach boundaries.
  • Maintain a dry, orderly and adequately illuminated work area.
08INFORMATION

Energized Work Controls

  • Consider energized work only when technically justified.
  • Verify authorization, risk assessment and an approved work method.
  • Use PPE and equipment suitable for shock and arc-flash hazards.

Critical Stop Criteria

🛑 Stop Work Now

STOP
×

Stop work immediately if electrical isolation and LOTO are not applied

×

Stop work if absence of voltage has not been properly verified

×

Stop work if exposed energized parts are not guarded or barricaded

×

Stop work if cords, plugs, panels or equipment are damaged

×

Stop work if qualified personnel, an approved method or required PPE are unavailable

Technical Control

Critical Values

0 V

Absence-of-voltage verification

LOTO

Lockout and tagout

GFCI / RCD

Ground-fault protection

QUALIFIED

Electrical work and testing

Test Sequence

Test on a known source → test the circuit → reverify on a known source

Reference

OSHA 29 CFR 1910.333 / 1910.334

OSHA 1910 Subpart S • 1926 Subpart K

Personal Protective Equipment

Required PPE

⛑️

Safety Helmet

EN 50365

🥽

Safety Glasses

EN 166

🧤

Voltage-Rated Gloves

EN 60903

🥾

Safety Footwear

EN 50321-1

🧥

Arc-Rated Clothing

IEC 61482

Select PPE based on voltage, shock and arc-flash hazards.

Voltage Rating

Gloves and equipment must match the working voltage.

Arc Hazard

Arc rating must be selected from the risk assessment.